Login Get Registered Catalog Browser Contact Us
Nexans in Qatar

About Nexans

Products and Solutions

Customer Service

Work at Nexans

News and Press

Go

Thermocouple EN 50288-7 XLPE Insulation IOS Armoured LC Fire retardant

Send link to this page print Your Nexans contact on this page
Thermocouple EN 50288-7 XLPE Insulation IOS Armoured LC Fire retardant - Thermocouple cables 170/300 V
- Individual & Overall Screen (IOS)
- With lead cover (LC)
- Aliphatic and aromatic hydrocarbons resistant
Standards
International  IEC 60332-3-22 Cat.A
Description

Applications

These compensation and extension cables are used with thermocouples for temperature measurements.They are well adapted to underground use in industrial applications, in moist areas, where chemical and mechanical protections are needed. The lead cover brings an enhanced resistance to aromatics hydrocarbons. The individual screening of each pair limits the consequence of crosstalk.

 

Design

Conductor:

Metal in accordance with the thermocouple, either solid cross section 0.5 mm² (1 x 0.8 mm), 1.34 mm² (1 x 1.30 mm) or flexible cross-section 1 mm² (14 x 0.30 mm)

Insulation:

Cross-linked polyethylene (XLPE)

Individual screen:

Binder tape

Tinned copper drain wire

Aluminium backed polyester tape

Binder tape

Overall screen:

Binder tape

Tinned copper drain wire

Aluminium backed polyester tape

Bedding (inner sheath):

Polyvinyl chloride (PVC)

Colour : black or depends on thermocouple type

Lead cover 

Bedding (intermediate sheath):

Polyvinyl Chloride (PVC)

Colour : black or depends on thermocouple type

Armour:

Galvanized steel wires (SWA)

Outer sheath:

Polyvinyl chloride (PVC)

Colour: depends on thermocouple type

 

Core identification

See "identification sheet"

 

Marking

NEXANS 279 XLPE/IND+OA.SCR/PVC/LC/PVC/SWA/PVC 170/300 V Nber of pairs & cross section Type of thermocouple IEC 60332-3-22(A) MM YYYY Manufacturing number + meter marking.

 

Standards

EN 50288-7 (Design guide-lines)

HD 446.3 S1



Related documents
  Identification sheet/Identification  (151.1kb)



 TOP
Characteristics
Construction characteristics
Insulation PRC  
Individual screen Tinned copper drain wire + aluminium/polyester tape  
Overall screen Tinned copper drain wire + aluminium/polyester tape  
Inner sheath PVC  
Lead Sheath Yes  
Intermediate sheath PVC  
Armour type Galvanized steel wires  
Outer sheath Tight buffer  
Protection Yes  
Electrical characteristics
Rated Voltage Uo/U (Um) 170/300V  
Mechanical characteristics
Mechanical resistance to impacts Good  
Usage characteristics
Fire retardant IEC 60332-3-22  
Chemical resistance Aliphatic and aromatic hydrocarbons resistant  
Electro magnetic interference resistance Yes  
Operating temperature, range -20 .. 60°C  
Max. conductor temperature in service 90°C  
Standard EN  

 TOP
Your selection
Conductor cross-section  mm²
Number of pairs  
Apply
Reset
Results   12/12
Select all Items Nexans ref. Name Cross section (mm²) nb pairs
Make to order product EN 50288-7 XLPE Insulation IOS Armoured LC 5x2x0.5 0.5 5
Make to order product EN 50288-7 XLPE Insulation IOS Armoured LC 10x2x0,5 0.5 10
Make to order product EN 50288-7 XLPE Insulation IOS Armoured LC 20x2x0,5 0.5 20
Make to order product EN 50288-7 XLPE Insulation IOS Armoured LC 30x2x0,5 0.5 30
Make to order product EN 50288-7 XLPE Insulation IOS Armoured LC 5x2x1 1 5
Make to order product EN 50288-7 XLPE Insulation IOS Armoured LC 10x2x1 1 10
Make to order product EN 50288-7 XLPE Insulation IOS Armoured LC 20x2x1 1 20
Make to order product EN 50288-7 XLPE Insulation IOS Armoured LC 30x2x1 1 30
Make to order product EN 50288-7 XLPE Insulation IOS Armoured LC 5x2x1,34 1.34 5
Make to order product EN 50288-7 XLPE Insulation IOS Armoured LC 10x2x1,34 1.34 10
Make to order product EN 50288-7 XLPE Insulation IOS Armoured LC 20x2x1,34 1.34 20
Make to order product EN 50288-7 XLPE Insulation IOS Armoured LC 30x2x1,34 1.34 30
Add to favorites

 TOP
* Thermocouple type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TC  – Copper/copper nickel for copper/copper nickel thermocouple

 

 

 

 

 

 

 

JC   – Iron/copper nickel for iron/copper nickel thermocouple

 

 

 

 

 

 

 

EC  – Nickel chromium/copper nickel for nickel chromium/copper nickel thermocouple

 

 

 

 

 

 

 

KC  – Nickel chromium/nickel aluminium for nickel chromium/nickel aluminium thermocouple

 

 

 

 

 

 

 

KCA  – Iron/copper nickel for nickel chromium/nickel aluminium thermocouple

 

 

 

 

 

 

 

KCB  – Copper/copper nickel for nickel chromium/nickel aluminium thermocouple

 

 

 

 

 

 

 

NC  – Nickel chromium silicium/nickel silicium for nickel chromium silicium/nickel silicium thermocouple

 

 

 

 

 

 

 

SC RC – Copper/copper nickel for platinium rhodium thermocouple

 

 

 

 

 

 

 

BC  – Copper/copper alloy for platinium rhodium/platinium rhodium thermocouple

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


 TOP
Selling delivery information

Other fire performances IEC 60332-1 or IEC 60332-3-24(C) on request.


Minimum bending radius:

10 x outer diameter
To be doubled during laying operations



Nexans © copyright 2001 - 2012   Legal Notice | Contact Us | Site Map