EN 50288-7 Hypron® XLPE Insulation OS Unarmoured Fire Retardant

Send link to this page print Your Nexans contact on this page
EN 50288-7 Hypron® XLPE Insulation OS Unarmoured Fire Retardant - Instrumentation cables 170/300 V
- Overall Screen (OS)
- Lead free
- Aliphatic and aromatic hydrocarbons resistant
Standards
International  IEC 60332-3-22 Cat.A
Description

Applications

These instrumentation and communication cable are used to transmit analogue or digital signals in measurement and process control in moist areas and where aliphatic and aromatic hydrocarbons may be present. Hypron® offers an alternative to conventional lead covered cable and is an environmental friendly solution

 

Design

Conductor:

Stranded bare copper class 2

Insulation:

Cross-linked polyethylene (XLPE)

Binder tape

Bedding

Inner sheath:

Polyvinyl chloride (PVC). 

Colour: black.

Overall screen/sealing barrier

Tinned copper drain wire, 

Aluminium backed polyethylene tape

Bedding:

High density polyethylene (PE)

Colour: black

Special sheath (intermediate sheath):

Polyamide

Outer sheath:

Polyvinyl chloride (PVC). 

Colour: black. 

Other colour on request.

 

 

Core identification

Pair: white - black
Quad: white - black - red - blue (2 pair cables assembled as a quad)
White core printed with pair number
 

Marking

NEXANS 279 XLPE/PVC/AL/HDPE/NC/PVC 170/300V Nber of pairs & cross-section Cu IEC 60332-3-22(A) MM YYYY Manufacturing number + metric marking

 

Standards

EN 50288-7 (Design guide-lines)



Related documents
  Electrical_characteristics  (30.7kb)



 TOP
Characteristics
Construction characteristics
Conductor material Bare copper  
Type of conductor Stranded, Class 2  
Insulation PRC  
Inner sheath PVC  
Overall screen Tinned copper drain wire + aluminium/polyethylene tape  
Material of bedding High-density polyethylene (PE)  
Intermediate sheath Polyamide  
Outer sheath Tight buffer  
Lead free Yes  
Protection no  
Electrical characteristics
Rated Voltage Uo/U (Um) 170/300V  
Usage characteristics
Fire retardant IEC 60332-3-22  
Chemical resistance Aliphatic and aromatic hydrocarbons resistant  
Electro magnetic interference resistance Yes  
Operating temperature, range -20 .. 60°C  
Max. conductor temperature in service 90°C  
Standard EN  

 TOP
Your selection
Number of pairs  
Conductor cross-section  mm²
Apply
Reset
Results   30/30
Select all Items Nexans ref. Name nb pairs Cross section (mm²)
Make to order product EN 50288-7 Hypron® XLPE OS Unarmoured 1x2x0,5 1 0.5
Make to order product EN 50288-7 Hypron® XLPE OS Unarmoured 2x2x0,5 2 0.5
Make to order product EN 50288-7 Hypron® XLPE OS Unarmoured 5x2x0,5 5 0.5
Make to order product EN 50288-7 Hypron® XLPE OS Unarmoured 10x2x0,5 10 0.5
Make to order product EN 50288-7 Hypron® XLPE OS Unarmoured 20x2x0,5 20 0.5
Make to order product EN 50288-7 Hypron® XLPE OS Unarmoured 30x2x0,5 30 0.5
Make to order product EN 50288-7 Hypron® XLPE OS Unarmoured 1x2x0,75 1 0.75
Make to order product EN 50288-7 Hypron® XLPE OS Unarmoured 2x2x0,75 2 0.75
Make to order product EN 50288-7 Hypron® XLPE OS Unarmoured 5x2x0,75 5 0.75
Make to order product EN 50288-7 Hypron® XLPE OS Unarmoured 10x2x0,75 10 0.75
Make to order product EN 50288-7 Hypron® XLPE OS Unarmoured 20x2x0,75 20 0.75
Make to order product EN 50288-7 Hypron® XLPE OS Unarmoured 30x2x0,75 30 0.75
Make to order product EN 50288-7 Hypron® XLPE OS Unarmoured 1x2x1 1 1
Make to order product EN 50288-7 Hypron® XLPE OS Unarmoured 2x2x1 2 1
Make to order product EN 50288-7 Hypron® XLPE OS Unarmoured 5x2x1 5 1
Make to order product EN 50288-7 Hypron® XLPE OS Unarmoured 10x2x1 10 1
Make to order product EN 50288-7 Hypron® XLPE OS Unarmoured 20x2x1 20 1
Make to order product EN 50288-7 Hypron® XLPE OS Unarmoured 30x2x1 30 1
Make to order product EN 50288-7 Hypron® XLPE OS Unarmoured 1x2x1,5 1 1.5
Make to order product EN 50288-7 Hypron® XLPE OS Unarmoured 2x2x1,5 2 1.5
Make to order product EN 50288-7 Hypron® XLPE OS Unarmoured 5x2x1,5 5 1.5
Make to order product EN 50288-7 Hypron® XLPE OS Unarmoured 10x2x1,5 10 1.5
Make to order product EN 50288-7 Hypron® XLPE OS Unarmoured 20x2x1,5 20 1.5
Make to order product EN 50288-7 Hypron® XLPE OS Unarmoured 30x2x1,5 30 1.5
Make to order product EN 50288-7 Hypron® XLPE OS Unarmoured 1x2x2,5 1 2.5
Make to order product EN 50288-7 Hypron® XLPE OS Unarmoured 2x2x2,5 2 2.5
Make to order product EN 50288-7 Hypron® XLPE OS Unarmoured 5x2x2,5 5 2.5
Make to order product EN 50288-7 Hypron® XLPE OS Unarmoured 10x2x2,5 10 2.5
Make to order product EN 50288-7 Hypron® XLPE OS Unarmoured 20x2x2,5 20 2.5
Make to order product EN 50288-7 Hypron® XLPE OS Unarmoured 30x2x2,5 30 2.5
Add to favorites

 TOP
Selling delivery information

Other fire performances IEC 60332-1 or IEC 60332-3-24(C) on request.


Minimum bending radius:

15 x outer diameter
To be doubled during laying operations


Tinned copper conductors available on request