(N)A2XH 0.6/1kV

New
Send link to this page print Your Nexans contact on this page
(N)A2XH 0.6/1kV singlecore or multicore XLPE-insulated cables with aluminium solid/stranded conductor and halogen-free sheath ALSECURE in acc. with DIN VDE 0276-604 Part 5G Flame retardent acc. IEC 60332-1-2.
Standards
International  IEC 60332-1; IEC 60754; IEC 61034
Description

Construction

Conductor of sector-shaped solid or round solid/stranded aluminium wires - insulation of cross-linked polyethylene (XLPE) -extruded halogen-free filling compound - flame retardant sheath - Polyoelfin-Compound Type HM4

Application

especially flame redundant; outdoors, in concrete, indoors and in cable ducts where no mechanical damage is to be expected

 

This product is also part of our Windlink® offer dedicated to wind turbines.
 


 TOP
Characteristics
Construction characteristics
Conductor material Aluminium/polyester tape  
Outer sheath HFFR (Halogene Free Flame Retardant)  
Halogen free IEC 60754  
Electrical characteristics
Test voltage 4kV  
Rated Voltage Uo/U (Um) 0.6/1 kV  
Maximum operating voltage 1.2kV  
Frequence 50Hz  
Usage characteristics
Minimum installation temperature -20°C  
Maximum operating temperature 90°C  
Minimum operating temperature -40°C  
Short-circuit max. conductor temperature 250°C  
Fire retardant IEC 60332-1  
Smoke density IEC 61034  
Gases corrosivity IEC 60754  

 TOP
Your selection
Number of cores  
Conductor cross-section  mm²
Nominal insulation thickness  mm
Average sheath thickness  mm
Minimum outer diameter  mm
Maximum outer diameter  mm
With Green/Yellow core  
Approximate net weight  kg
Permissible current rating in open air  A
Bending factor when laying  (xD)
Apply
Reset
Results   22/22
Select all Items Nexans ref. Nb. of cores Cross section (mm²) Nom. insulation thick. (mm) Average sheath thickness (mm) Min. outer diam. (mm) Max. outer diam. (mm) Green/ Yellow core Approx. net weight (kg) Perm. current rating open air (A) Bending factor when laying ((xD))
Make to order product VAL195H1   New 1 95 1.1 1.3 16.0 20.0 No 405.0 252 15
Make to order product VAL1120H1   New 1 120 1.2 1.3 17.0 22.0 No 490.0 295 15
Make to order product VAL1150H1   New 1 150 1.4 1.3 18.0 23.0 No 580.0 339 15
Make to order product 61690129   New 1 185 1.6 1.4 20.0 25.0 No 700.0 395 15
Make to order product VAL1240H1   New 1 240 1.7 1.4 22.0 28.0 No 880.0 472 15
Make to order product VAL1300H1   New 1 300 1.8 1.5 25.0 30.0 No 1080.0 547 15
Make to order product VAL1400H1   New 1 400 2.0 1.5 28.0 33.0 No 1370.0 643 15
Make to order product VAL1500H1   New 1 500 2.2 1.6 32.0 37.0 No 1760.0 754 15
Make to order product VAL1630H1   New 1 630 2.4 1.7 36.0 41.0 No 2200.0 882 15
Make to order product VAL395H1   New 3 95 1.1 1.6 28.0 34.0 No 1300.0 12
Make to order product VAL3120H1   New 3 120 1.2 1.7 32.0 37.0 No 1620.0 12
Make to order product VAL3150H1   New 3 150 1.4 1.7 35.0 40.0 No 1930.0 12
Make to order product VAL3185H1   New 3 185 1.6 1.9 38.0 44.0 No 2380.0 12
Make to order product VAL3240H1   New 3 240 1.7 2.0 42.0 48.0 No 2970.0 12
Make to order product VAL435H1   New 4 35 0.9 1.5 24.0 28.0 Yes 890.0 126 12
Make to order product VAL450H1   New 4 50 1.0 1.5 25.0 30.0 Yes 1030.0 149 12
Make to order product VAL470H1   New 4 70 1.1 1.6 29.0 34.0 Yes 1350.0 191 12
Make to order product VAL495H1   New 4 95 1.1 1.7 32.0 37.0 Yes 1710.0 234 12
Make to order product VAL4120H1   New 4 120 1.2 1.7 36.0 41.0 Yes 2120.0 273 12
Make to order product VAL4150H1   New 4 150 1.4 1.8 41.0 46.0 Yes 2600.0 311 12
Make to order product VAL4185H1   New 4 185 1.6 1.9 44.0 49.0 Yes 3160.0 360 12
Make to order product VAL4240H1   New 4 240 1.7 2.0 48.0 53.0 Yes 3950.0 427 12
Add to favorites

 TOP
Selling delivery information
Voltage test in our plant: 5 minutes per core a) 4 kV ac voltage or b) 12 kV dc voltage