Login Get Registered Catalog Browser Contact Us
Nexans in Qatar

About Nexans

Products and Solutions

Customer Service

Work at Nexans

News and Press

Go

U-1000 AR2V (industrial rigid unarmoured)

Send link to this page print Your Nexans contact on this page
U-1000 AR2V (industrial rigid unarmoured) Low voltage power cable for fixed application,
Aluminium conductor, XLPE insulation and PVC outer sheath.
Standards
National  NF C 32-321
Description

Application

U-1000 AR2V aluminium cables can be used in all low voltage power installations.
This product is used in photovoltaic applications (branded KEYLIOS®)

 

Installation

These cables can be fixed on cable trays, within conduits or fixed to walls.
They also can be buried directly with extra mechanical protection.

 

Design

  • Conductor: stranded circular aluminium - class 2 according to NFC 32-013 / IEC 60228 / HD 383
  • Insulation: XLPE - cores identification by colours
  • Laying up (for multi conductors): with non hygroscopic filler
  • Outer sheath : Lead free black PVC 

Construction according to AD8 is possible on request

  

Marking

N (x ou G) S mm² U-1000 AR2V NF - USE N° Usine S.Y + Sans Pb

  • N = number of cores
  • S = section in mm²
  • G = with Green-Yellow
  • x = without Green-Yellow

 TOP
Characteristics
Construction characteristics
Conductor material Aluminium  
Conductor flexibility Stranded class 2  
Insulation XLPE (chemical)  
Outer sheath PVC  
Sheath colour Black  
Lead free Yes  
Electrical characteristics
Rated Voltage Uo/U (Um) 0.6/1 kV  
Mechanical characteristics
Mechanical resistance to impacts Good  
Usage characteristics
Max. conductor temperature in service 90°C  
Short-circuit max. conductor temperature 250°C  
Operating temperature, range -25 .. 60°C  
Weather resistance Very good  
Flame retardant C2, NF C 32-070  
Chemical resistance Accidental  
Water proof Very good  

 TOP
Your selection
Number of cores  
Conductor cross-section  mm²
With smaller neutral conductor  
Max. DC resistance of the conductor at 20°C  Ohm/km
Apply
Reset
Results   33/33
Select all Items Nexans ref. Country ref. Name Nb. of cores Cross section (mm²) With smaller neutral conductor Max. DC resist. conductor 20°C (Ohm/km)
10043987 01362120 U-1000 AR2V 1x120 cut to length 1 120 No 0.253
10043988 01362130 U-1000 AR2V 1x150 cut to length 1 150 No 0.206
10043989 01362140 U-1000 AR2V 1x185 cut to length 1 185 No 0.164
10043990 01362150 U-1000 AR2V 1x240 cut to length 1 240 No 0.125
10043991 01362160 U-1000 AR2V 1x300 cut to length 1 300 No 0.1
10044029 01362080 U-1000 AR2V 1x35 cut to length 1 35 No 0.868
10043992 01362170 U-1000 AR2V 1x400 cut to length 1 400 No 0.0778
10043984 01362090 U-1000 AR2V 1x50 cut to length 1 50 No 0.641
10044014 01362190 U-1000 AR2V 1x630 cut to length 1 630 No 0.0469
10043985 01362100 U-1000 AR2V 1x70 cut to length 1 70 No 0.443
10043986 01362110 U-1000 AR2V 1x95 cut to length 1 95 No 0.32
10057428 01362270 U-1000 AR2V 2x25 Stranded class 2 cut to length 2 25 No 0.868
10098424 01363001 U-1000 AR2V 2x35 Stranded class 2 cut to length 2 35 No 0.868
10043999 01362920 U-1000 AR2V 3x120+70 cut to length 4 120 Yes 0.253
10044000 01362940 U-1000 AR2V 3x150+70 cut to length 4 150 Yes 0.206
10044001 01362960 U-1000 AR2V 3x185+95 cut to length 4 185 Yes 0.164
10044002 01362970 U-1000 AR2V 3x240+95 cut to length 4 240 Yes 0.125
10057451 01362400 U-1000 AR2V 3x35 cut to length 3 35 No 0.868
10057430 01362490 U-1000 AR2V 3x50 cut to length 3 50 No 0.641
10043993 01362500 U-1000 AR2V 3x70 cut to length 3 70 No 0.443
10043997 01362890 U-1000 AR2V 3x70+50 cut to length 4 70 Yes 0.443
10044012 01362510 U-1000 AR2V 3x95 cut to length 3 95 No 0.32
10043998 01362900 U-1000 AR2V 3x95+50 cut to length 4 95 Yes 0.32
10057449 01362670 U-1000 AR2V 4G25 cut to length 4 25 No 0.868
10057448 01362600 U-1000 AR2V 4G35 cut to length 4 35 No 0.868
10057458 01362730 U-1000 AR2V 4x150 cut to length 4 150 No 0.206
10057440 01362750 U-1000 AR2V 4x240 cut to length 4 240 No 0.125
10057463 01362675 U-1000 AR2V 4x25 cut to length 4 25 No 0.868
10057334 01248983 U-1000 AR2V 4x35 Solid class 1 cut to length 4 35 No 0.868
10043983 01362680 U-1000 AR2V 4x35 cut to length 4 35 No 0.868
10043994 01362690 U-1000 AR2V 4x50 cut to length 4 50 No 0.641
10043995 01362700 U-1000 AR2V 4x70 cut to length 4 70 No 0.443
10043996 01362710 U-1000 AR2V 4x95 cut to length 4 95 No 0.32
Add to favorites

 TOP
New cores identification
Core identification in accordance with HD 308 S2 (October 2001)Identification of cores in cables and flexible cords.

 

Number of cores

HD 308 S2 since january 2004

G (earth core)

X (without earth core)

1

Black (preferential)

Black (preferential)

2

Blue + Brown

Blue + Brown

3*

Green - Yellow + Blue + Brown 

Brown + Black + Grey

3**

 

Blue + Brown + Black

4

Green - Yellow + Brown + Black + Grey

Blue + Brown + Black + Grey

5

Green - Yellow + Blue + Brown + Black + Grey

Blue + Brown + Black + Grey + Black

>  5

White printed numbers + 1 Green - Yellow

White printed numbers

* For the cables without Green/Yellow with a cross-section >4mm²

** For the cables without Green/Yellow with a cross-section of 1,5mm² & 2,5mm²


 TOP
Laying conditions

Without mechanical protection, those cables can be fixed on the wall, cables trays or cable laders.

In buildings with explosion risks, they will be installed with particular protection. In this case, step down of 15% current carrying capacities.

 

Pulling on cable conductors

Tensile stress per mm2 of section shall in no case exceed 5 daN for LV aluminium cable.

The maximum pulling load must never exceed 2000 daN even rule above-mentionned sometimes leads to higher values for large section of cable.


 TOP