Login Get Registered Catalog Browser Contact Us
Nexans in Qatar

About Nexans

Products and Solutions

Customer Service

Work at Nexans

News and Press

Go

H.V BFOU 3C+1EARTH [P6], [P6/P13], [P7], [P7/P14]

New
Send link to this page print Your Nexans contact on this page
H.V BFOU 3C+1EARTH [P6], [P6/P13], [P7], [P7/P14]
  • Power circuit above 1kV.
  • Fixed installation in both explosion risk and safe areas.
  • Medium voltage power cables for emergency and critical systems.
  • Maximum operating conductor temperature 90°C
Kukdong
Standards
International  IEC 60092-351; IEC 60092-354; IEC 60092-359; IEC 60331; IEC 60332-3 Cat.A; IEC 60754-1; IEC 61034; IEC 61034-2
National  NEK 606; NEK 606
Description

Construction Details
  - Conductor : Circular tinned stranded copper as per IEC 60228, Class 2
  - Conductor screen : Semi-conducting tape
  - Fire proof layer : Mica/Glass tape
  - Insulation : Halogen Free Ethylene Propylene Rubber
  - Insulation screen : Semi-conducting compound and Semi-conducting tape
  - Metallic screen : Copper wire braid
  - Cabling (with filler)
  - Inner sheath : Halogen-free thermosetting compound, SHF2 
  - Armour : Copper wire braid
  - Outer sheath :  Halogen-free thermosetting compound, SHF2 or SHF Mud

Earth conductor 
  - 50% of current-carrying phase conductor

Standard Applied
 
- Design guideline : NEK 606-2009 & IEC 60092-354
  - Material
    Insulation : EPR as per IEC 60092-351
    Sheath : SHF2 as per IEC 60092-359
  - Flame retardant : IEC 60332-3-22, Cat.A
  - Fire resistant : IEC 60331-21
  - Halogen free properties : IEC 60754-1,2
  - Low smoke properties : IEC 61034-1,2
  - Mud resistant : NEK 606-2009
  - Cold properties : CSA C22.2
  - Sunlight resistance : UL 1581
 
Identification of color
  - Insulation (colored tape under the metalic screen)
    3C : Grey, Black, Red
    Earth : Green/Yellow stripe (0.6/1kV insulation level)
    Note) Any other colors purchaser required

  - Outer sheath : Red
    Note) Any other colors purchaser required
 
Type approval 
  - ABS, BV, DNV, LR


 TOP
Characteristics
Dimensional characteristics
Number of cores 3  
Number of ground conductors 1.0  
Diameter of wire braids 0.4mm  

 TOP
Your selection
Conductor cross-section  mm²
Average insulation thickness  mm
Inner sheath thickness  mm
Diameter over inner sheath  mm
Diameter over armour  mm
Average sheath thickness  mm
Nominal outer diameter  mm
Approximate weight  kg/km
Rated Voltage Uo/U (Um)  
Apply
Reset
Results   21/21
Select all Items Nexans ref. Name Cross section (mm²) Av. insul. thickness (mm) Inner sheath thick. (mm) Diam. over inner sheath (mm) Diam. over armour (mm) Average sheath thickness (mm) Nom. outer diam. (mm) Approx. weight (kg/km) Rated Voltage Uo/U (Um)
Make to order product   New 3.6/6kV BFOU [P6], [P6/P13] 25 3.0 2.5 45.4 47.5 1.8 51.5 4260 3.6/6 kV
Make to order product   New 3.6/6kV BFOU [P6], [P6/P13] 35 3.0 2.6 48.9 51.0 1.9 55.2 5030 3.6/6 kV
Make to order product   New 3.6/6kV BFOU [P6], [P6/P13] 50 3.0 2.7 51.3 53.4 1.9 57.6 5650 3.6/6 kV
Make to order product   New 3.6/6kV BFOU [P6], [P6/P13] 70 3.0 2.8 55.6 57.7 2.0 52.1 6870 3.6/6 kV
Make to order product   New 3.6/6kV BFOU [P6], [P6/P13] 95 3.0 3.0 60.4 62.5 2.2 67.3 8390 3.6/6 kV
Make to order product   New 3.6/6kV BFOU [P6], [P6/P13] 120 3.0 3.2 64.6 66.7 2.3 71.7 9870 3.6/6 kV
Make to order product   New 3.6/6kV BFOU [P6], [P6/P13] 150 3.0 3.3 69 71.1 2.4 76.3 11500 3.6/6 kV
Make to order product   New 6/10kV BFOU [P7], [P7/P14] 25 3.4 2.5 47.1 49.2 1.8 53.2 4470 6 / 10 (12) kV
Make to order product   New 6/10kV BFOU [P7], [P7/P14] 35 3.4 2.7 50.6 52.7 1.9 56.9 5260 6 / 10 (12) kV
Make to order product   New 6/10kV BFOU [P7], [P7/P14] 50 3.4 2.7 52.9 55.0 2.0 59.4 5900 6 / 10 (12) kV
Make to order product   New 6/10kV BFOU [P7], [P7/P14] 70 3.4 2.9 57.3 59.4 2.1 64.0 7150 6 / 10 (12) kV
Make to order product   New 6/10kV BFOU [P7], [P7/P14] 95 3.4 3.1 62.1 64.2 2.2 69.0 8660 6 / 10 (12) kV
Make to order product   New 6/10kV BFOU [P7], [P7/P14] 120 3.4 3.2 66.2 68.3 2.3 73.3 10130 6 / 10 (12) kV
Make to order product   New 6/10kV BFOU [P7], [P7/P14] 150 3.4 3.4 70.7 72.8 2.4 78.0 11800 6 / 10 (12) kV
Make to order product   New 8.7/15kV BFOU ,BFOU [MR] 25 4.5 2.7 52.1 54.2 2.0 58.6 5180 8.7 / 15 (17.5) kV
Make to order product   New 8.7/15kV BFOU ,BFOU [MR] 35 4.5 2.8 55.1 57.2 2.0 61.6 5890 8.7 / 15 (17.5) kV
Make to order product   New 8.7/15kV BFOU ,BFOU [MR] 50 4.5 2.9 57.8 59.9 2.2 64.5 6630 8.7 / 15 (17.5) kV
Make to order product   New 8.7/15kV BFOU ,BFOU [MR] 70 4.5 3.1 62.1 64.2 2.2 69.0 7910 8.7 / 15 (17.5) kV
Make to order product   New 8.7/15kV BFOU ,BFOU [MR] 95 4.5 3.3 66.6 68.7 2.3 73.7 9410 8.7 / 15 (17.5) kV
Make to order product   New 8.7/15kV BFOU ,BFOU [MR] 120 4.5 3.4 70.7 72.8 2.4 78.0 10920 8.7 / 15 (17.5) kV
Make to order product   New 8.7/15kV BFOU ,BFOU [MR] 150 4.5 3.6 75.3 77.4 2.5 82.8 12670 8.7 / 15 (17.5) kV
Add to favorites