MPRXCX® 6/10 (12) kV

Send link to this page print Your Nexans contact on this page
MPRXCX® 6/10 (12) kV This product is part of our Shiplink® offer
Standards
International  IEC 60092-350; IEC 60092-351; IEC 60092-354; IEC 60092-359; IEC 60228; IEC 60332-1; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034
Description

Application

MPRXCX® type is used for fixed installations on board of ships at all levels.
Semi conductive layer over insulation is easily stripable.

MPRXCX® type withstands IEC 60332-3 fire test on bunched cables and performs to the SOLAS requirements.


Design

  1. Conductor
    Stranded Bare copper class 2
     
  2. Extruded semi conductor
     
  3. Insulation
    XLPE (cross linked polyethylene)
     
  4. Screen
    Extruded semi conductor
    Bare copper tape
     
  5. Inner covering
    Polyolefin
     
  6. Armouring
    Bare copper braid
     
  7. Outer sheath:
    Polyolefin SHF1
    Colour: red
    SHF2 on request
     

Marking

NEXANS 205 MPRXCX® 3.6/6 kV "n" x "s" mm² 90°C IEC 60332-3-22 "WW/YY" + Metric Marking

 

Core Identification

By coloured thread:
blue - white - red


 TOP
Characteristics
Construction characteristics
Conductor material Bare copper  
Material of the inner semi-conductor Extruded  
Insulation XLPE (Cross-linked Polyethylene)  
Screen Extruded semi-conductor, bare copper tape  
Inner sheath Polyolefin  
Armour type Bare copper braid  
Outer sheath Polyolefin  
Halogen free IEC 60754-1  
Sheath colour Red  
Electrical characteristics
Rated Voltage Uo/U (Um) 6 / 10 (12) kV  
Mechanical characteristics
Corrosivity IEC 60754-2  
Usage characteristics
Standard IEC  
Fire retardant IEC 60332-3-22  
Smoke density IEC 61034  
Gases toxicity No  
Operating temperature, range -30 .. 80°C  
Electro magnetic interference resistance Yes  
Flame retardant IEC 60332-1  

 TOP
Your selection
Permissible current rating in open air  A
Conductor cross-section  mm²
Number of cores  
Apply
Reset
Results   7/7
Select all Items Nexans ref. Country ref. Name Perm. current rating open air (A) Cross section (mm²) Nb. of cores
Make to order product 10045876 01101921 MPRXCX 6/10KV 1X120 338 120 1
Make to order product 10046231 01105704 MPRXCX 6/10KV 1X240 522 240 1
Make to order product 10035157 01105739 MPRXCX 6/10KV 1X70 241 70 1
Make to order product 10045502 01099762 MPRXCX 6/10KV 3X120 237 120 3
Make to order product 10013281 01101195 MPRXCX 6/10KV 3X35 109 35 3
Make to order product 10045500 01099760 MPRXCX 6/10KV 3X70 169 70 3
Make to order product 10045501 01099761 MPRXCX 6/10KV 3X95 204 95 3
Add to favorites

 TOP