Login Get Registered Catalog Browser Contact Us
Nexans in Qatar

About Nexans

Products and Solutions

Customer Service

Work at Nexans

News and Press

Go

RHEYFIRM®(RTS) R-(N)TSCGEWTOEUS

Send link to this page print Your Nexans contact on this page
RHEYFIRM®(RTS) R-(N)TSCGEWTOEUS Reeling Cables
1.8/3 (3.6) kV
up to 18/30 (36) kV
UL File E302473
Standards
International  Nexans specification
Description

Applications

Flexible reeling cable for energy supply. Especially for high and extreme mechanical stress, e.g. torsional stress and high reeling speed up to 270 m/min. For deflection into different planes. 
Main applications: Ship To Shore cranes (STS), Rail Mounted Gantry cranes (RMG), Ship Unloader, Stacker Reclaimer and other heavy mobile equipment.
 

Design

Conductor
Flexible stranded plain copper, "FSC" better than DIN EN / IEC 60228 class 5

Insulation

  • Inner semi-conductive stress control layer
  • New special elastomeric insulation compound "RHEYCLEAN" based on EPR
  • Outer semi-conductive insulation shield layer, "RHEYSTRIP", easy strip (Thermostrip)

Protective conductor
Flexible stranded plain copper, "FSC" better than DIN EN / IEC 60228 class 5, semi-conductive layer

Inner sheath
Special synthetic rubber compound better than GM1b acc. DIN VDE 0207 part 21

Reinforcement
Braid made of synthetic threads with very high tensile strength as a protection against twist stress and pressure loads

Outer sheath
Heavy duty chlorinated rubber compound 5GM5 acc. DIN VDE 0207 part 21.
New special sandwich construction for optimal flexibility, abrasion resistance and heavy load.

Marking


e.g.:
RHEYFIRM(RTS)  R-(N)TSCGEWTOEUS  3x120+3x70/3  6/10 kV
I NEXANS I  year

 

 

Core identification


Six core design :
- three phase cores
- three protective/earth cores in the interstices
Length of lay is optimized for the different applications.


 TOP
Characteristics
Construction characteristics
Conductor material Plain copper  
Mechanical characteristics
Cable flexibility Flexible  
Mechanical resistance to impacts Excellent  
Usage characteristics
Moisture resistance Yes  
Oil resistance EN 60811-2-1  
Limit surface temperature, flexible application -40 .. 80°C  
Ozone resistance Yes  
U.V resistance Yes  
Flame retardant EN 60332-1-2  

 TOP
Your selection
Construction type  
Rated Voltage Uo/U (Um)  
Minimum outer diameter  mm
Maximum outer diameter  mm
Approximate weight  kg/km
Tensile strength  N
Apply
Reset
Results   15/15
Select all Items Nexans ref. Construction type Rated Voltage Uo/U (Um) Min. outer diam. (mm) Max. outer diam. (mm) Approx. weight (kg/km) Tensile strength (N)
Make to order product 71306372 3X120+3X70/3 12/20 kV 61.0 64.0 6660 5400
Make to order product 71308288 3X120+3X70/3 18/30 kV 54.0 57.0 6120 7200
Make to order product 71308279 3x185+3x95/3 18/30 kV 62.0 65.0 8600 11100
Make to order product 71305275 3X120+3X70/3 18/30 kV 69.0 72.0 8050 7200
Make to order product 71308291 3X70+3X50/3 18/30 kV 64.0 67.0 8000 9000
Make to order product 71308278 3X120+3X70/3 18/30 kV 71.0 74.0 7990 9000
Make to order product 71303281 3X120+3X70/3 3.6/6 kV 58.0 61.0 6350 7200
Make to order product 71303271 3x185+3x95/3 3.6/6 kV 68.0 71.0 9300 11100
Make to order product 71303270 3x185+3x95/3 3.6/6 kV 57.0 60.0 7180 9000
Make to order product 71303282 3X120+3X70/3 3.6/6 kV 58.0 61.0 6600 7200
Make to order product 71304269 3X50+3X50/3 6/10 kV 64.0 67.0 8000 9000
Make to order product 71303285 3X120+3X70/3 6/10 kV 61.0 64.0 6950 7200
Make to order product 71303286 3x95+3x50/3 6/10 kV 66.0 69.0 8210 9000
Make to order product 71308302 3x95+3x50/3 6/10 kV 69.0 72.0 8710 9000
Make to order product 71308290 3X70+3X50/3 8.7/15 kV 64.0 67.0 8000 9000
Add to favorites

 TOP
Mechanical properties

 

Tensile stress of the conductor

static
dynamic

15 N/mm²
30 N/mm²

Bending radii

acc. to DIN VDE 298-3
see construction characteristics

Tests

alternating/reversed bending test,
torsional resistance test,
reeling test


Electrical and Thermal properties

 

EMC

Excellent EMC compatibility due to 6 cores design

Nominal voltage
Maximum operating voltage in AC systems
Maximum operating voltage in DC systems

Uo/U
Um
Vm

1.8/3 kV to 18/30 kV
1.2 x U
1.8 x U

Test voltage (according to DIN VDE 0250 part 813)

11 to 45 kV in AC
27.5 to 107.5 kV in DC

Current rating (A)

according to DIN VDE 0298 part 4


 TOP
Selling delivery information

Options

  • Other sheath quality and colour on request
  • Pre-assembled with sealing ends upon request

RHEYFIRM®(RTS) R-(N)TSCGEWTOEUS   Conductors (66 kB)

Nexans © copyright 2001 - 2012   Legal Notice | Contact Us | Site Map